The Velo high Voltage Patch Panel 0(PP0)
Objective
The objective of the PP0 is to arrange and distribute the high voltage
channels from the multi channel power supply to the 56 core cables. PP0
will be located in the counting room and it is at this point that hybrid
guard will be connected to the high of the HV channel and thus powering
the third channel of the HV channel. It is also that at this point that
the current of the hybrid guard should be measured.
Implementation
- The power supply end has a 51 pin SLA.H51.LLZG(male connector)(09.41.34.268.7)
which will be populated with male 32 contacts
FFA.05.403.ZLA1(09.41.33.210.9).
- The patch panel 1 end has a 51 pin SLG.H51.LLZG(female connector) (09.41.34.258.9)
populated with 48 male contacts FFA.05.403.ZLA1(09.41.33.210.9).
Shopping List
- 7 51 pin SLA.H51.LLZBG .
- 7 51 pin SLG.H51.LLZG .
- 560 male contacts FFA.05.403.ZLA1 .