next up previous
Next: Pre-irradiation Characteristics Up: Characterisation of low pressure Previous: Introduction

Experimental

The low pressure vapour phase epitaxial GaAs was grown by Epitronics Corporation[4] on the surface of a 450 $\mu$m thick Hitachi Cable Horizontal Bridgeman GaAs substrate. The substrate was n$^{+}$ in nature with silicon doping at a concentration of 10$^{18}$ cm$^{-3}$. The VPE layer was n-type and varied in thickness across the wafer from approximately 240 $\mu$m to 125 $\mu$m. The surface of the VPE layer was chemo-mechanically polished with a H$_{2}$O$_{2}$:NH$_{4}$ solution at a pH of $7.9\pm0.1$, a process used in the preparation of LEC wafers at Glasgow University[5]. This process removed approximately 30 $\mu$m from the VPE layer and reduced surface imperfections.

Circular diodes of 4 mm is diameter were fabricated with metallic electrodes evaporated onto the front (VPE side) and back of the material. The front Schottky contact was a Ti/Pd/Au multi-layer while the back metallisation was Pd/Ge. The rear contact was not annealed and the ohmic contact was realised due to the n$^{+}$ substrate.

Electrical and charge collection characterisation were performed on the diodes. The electrical characterisations were carried out at 300 K with the use of a Keithley-237 source measurement unit and a Hewlett Packard 4274A multi-frequency LCR meter. The response of the diodes to alpha particle irradiation from an Am-241 source under vacuum and to 60 keV photons from an encapsulated Am-241 source were determined. Since the front of the alpha source was coated with surface contamination, which reduced the energy of the alpha particles, the average energy was determined with an over-depleted silicon detector to be 4.1 MeV. The diodes were biased and read-out with an EG$\&$G Ortec-142 pre-amplifier. The signal was shaped with an Ortec-485 post-amplifier with a shaping time of 500 ns and sent to a multichannel analyser.

Four of the VPE diodes were exposed to a fluence of $1.25\times 10^{14}$ 24 GeV/c protons cm$^{-2}$ to test their radiation hardness. The irradiation was performed at the CERN PS[6], Switzerland, at room temperature and without bias. The diodes were stored for three months at room temperature after irradiation before characterisation. No search was made for effects due to annealing over this period.


next up previous
Next: Pre-irradiation Characteristics Up: Characterisation of low pressure Previous: Introduction
www person 2000-11-22